Initialization and finalization

init :: MonadIO m => m Bool Source #

Initialize the library.

This function initializes the library. Calling it is not strictly necessary, as it will be called automatically when enumerating or opening devices if it’s needed. This function should be called at the beginning of execution however, if there is a chance of handles being opened by different threads simultaneously.

exit :: MonadIO m => m Bool Source #

Finalize the library.

This function frees all of the static data associated with the library. It should be called at the end of execution to avoid memory leaks.

Getting devices information

enumerate :: MonadIO m => Word32 -> Word32 -> m [DeviceInfo] Source #

Enumerate all devices for a given vendor ID and product ID. If you need to get all available devices, use detectDevices.

detectDevices :: MonadIO m => m [DeviceInfo] Source #

Enumerate all plugged in devices.

Accessing devices

data Device Source #

An opaque device.

vendorProductSerialDevice :: MonadIO m => Word16 -> Word16 -> Maybe String -> m (Maybe Device) Source #

Get a Device from the vendor ID, product ID and an optional serial number.

pathDevice :: MonadIO m => String -> m (Maybe Device) Source #

Get a Device from a path.

Sending data to devices

writeOutputReport :: MonadIO m => Device -> ByteString -> m Int Source #

Write an Output report to a HID device.

The first byte of data must contain the Report ID. For devices which only support a single report, this must be set to 0x0. The remaining bytes contain the report data. Since the Report ID is mandatory, calls to writeOutputReport will always contain one more byte(s) than the report contains. For example, if a hid report is 16 bytes long, 17 bytes must be passed to writeOutputReport, the Report ID (or 0x0, for devices with a single report), followed by the report data (16 bytes). In that example, the length passed in would be 17.

writeOutputReport will send the data on the first OUT endpoint, if one exists. If it does not, it will send the data through the Control Endpoint Endpoint 0).

sendFeatureReport :: MonadIO m => Device -> ByteString -> m Int Source #

Send a Feature report to the device.

Feature reports are sent over the Control endpoint as a Set_Report transfer. The first byte of data must contain the Report ID. For devices which only upport a single report, this must be set to 0x0. The remaining bytes contain the report data. Since the Report ID is mandatory, calls to sendFeatureReport will always contain one more byte than the report contains. For example, if a hid report is 16 bytes long, 17 bytes must be passed to sendFeatureReport: the Report ID (or 0x0, for devices which do not use numbered reports), followed by the report data (16 bytes). In that example, the length passed in would be 17.

Receiving data from devices

readInputReport :: MonadIO m => Device -> m (Maybe ByteString) Source #

Read an Input report from a HID device.

Input reports are returned to the host through the INTERRUPT IN endpoint. The first byte will contain the Report number if the device uses numbered reports.

readInputReportTimeout :: MonadIO m => Device -> Int -> m (Maybe ByteString) Source #

Read an Input report from a HID device with timeout.

Input reports are returned to the host through the INTERRUPT IN endpoint. The first byte will contain the Report number if the device uses numbered reports.

getFeatureReport :: MonadIO m => Device -> m (Maybe ByteString) Source #

Get a feature report from a HID device.

Set the first byte of data to the Report ID of the report to be read. Make sure to allow space for this extra byte in data. Upon return, the first byte will still contain the Report ID, and the report data will start in data[1].

getManufacturer :: MonadIO m => Device -> m String Source #

Get the manufacturer string from a HID device.

getProductName :: MonadIO m => Device -> m String Source #

Get the product name from a HID device.

getSerialNumber :: MonadIO m => Device -> m String Source #

Get the serial number string from a HID device.

getIndexedString :: MonadIO m => Device -> Int -> m String Source #

Get an indexed string from a HID device.

Blocking mode for devices

setBlocking :: MonadIO m => Device -> Bool -> m Bool Source #

Set the blocking mode of a device.

Getting errors

getError :: MonadIO m => Device -> m String Source #

Get last error.